.016 Bio- Kinetix Plus D-LX Archwire
Ref# : 101-102
10 - 20 Weeks
Objective: Initiate tooth movement, begin aligning/leveling teeth; correct rotation issues, start to develop arch
Recommended Archwire: .014 Bio-Kinetix Plus D-LX Archwire (Upper/Lower)
Options: Cases with severe crowding - use a .016 Bio-Kinetix Plus Archwire before moving to Phase 2.Out of stock
-
.013 Bio- Kinetix Plus D-LX Archwire
Ref# : 103-100
10 - 20 Weeks
Objective: Initiate tooth movement, begin aligning/leveling teeth; correct rotation issues, start to develop arch
Recommended Archwire: .014 Bio-Kinetix Plus D-LX Archwire (Upper/Lower)
Options: Cases with severe crowding - use a .016 Bio-Kinetix Plus Archwire before moving to Phase 2.Out of stock
-
.014 Bio- Kinetix Plus D-LX Archwire
Ref# : 103-101
10 - 20 Weeks
Objective: Initiate tooth movement, begin aligning/leveling teeth; correct rotation issues, start to develop arch
Recommended Archwire: .014 Bio-Kinetix Plus D-LX Archwire (Upper/Lower)
Options: Cases with severe crowding - use a .016 Bio-Kinetix Plus Archwire before moving to Phase 2.Out of stock
-
.018 Bio- Kinetix Plus D-LX Archwire
Ref# : 103-103
10 - 20 Weeks
Objective: Initiate tooth movement, begin aligning/leveling teeth; correct rotation issues, start to develop arch
Recommended Archwire: .014 Bio-Kinetix Plus D-LX Archwire (Upper/Lower)
Options: Cases with severe crowding - use a .016 Bio-Kinetix Plus Archwire before moving to Phase 2.Out of stock
-
.014 x .025 Bio- Kinetix Plus D-LX Archwire
Ref# : 103-104
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch.
Recommended Archwire: .014 x .025 Bio-Kinetix Plus D-LX Archwire (Upper/Lower) -place in well prepared arches .018 x .025 Bio-Kinetix Plus D-LX Archwire (Upper/Lower) - to express more torque control and prep for Stainless Steel Archwire
Out of stock
-
.016 x .025 Bio- Kinetix Plus D-LX Archwire
Ref# : 103-105
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch.
Recommended Archwire: .014 x .025 Bio-Kinetix Plus D-LX Archwire (Upper/Lower) -place in well prepared arches .018 x .025 Bio-Kinetix Plus D-LX Archwire (Upper/Lower) - to express more torque control and prep for Stainless Steel Archwire
Out of stock
-
.018 x .025 Bio- Kinetix Plus D-LX Archwire
Ref# : 103-106
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch.
Recommended Archwire: .014 x .025 Bio-Kinetix Plus D-LX Archwire (Upper/Lower) -place in well prepared arches .018 x .025 Bio-Kinetix Plus D-LX Archwire (Upper/Lower) - to express more torque control and prep for Stainless Steel Archwire
Out of stock
-
.016 x .025 34mm Nitanium Pro Form - 20 degrees Torque Archwire
Ref# : 103-107
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch. 34mm Options: Duration 4 - 6 weeks (Upper only) A) .017 x .025 and .019 x .025 Nitanium Arcwirestorque archwires for division 2 cases, where additional torque are indicated
Out of stock
-
.016 x .025 38mm Nitanium Pro Form - 20 degrees Torque Archwire
Ref# : 103-108
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch. 38mm Options: Duration 4 - 6 weeks (Upper only) A) .017 x .025 and .019 x .025 Nitanium Arcwirestorque archwires for division 2 cases, where additional torque are indicated
Out of stock
-
.017 x .025 34mm Nitanium Pro Form - 20 degrees Torque Archwire
Ref# : 103-109
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch. 34mm Options: Duration 4 - 6 weeks (Upper only) A) .017 x .025 and .019 x .025 Nitanium Arcwirestorque archwires for division 2 cases, where additional torque are indicated
Out of stock
-
.017 x .025 38mm Nitanium Pro Form - 20 degrees Torque Archwire
Ref# : 103-110
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch. 38mm Options: Duration 4 - 6 weeks (Upper only) A) .017 x .025 and .019 x .025 Nitanium Arcwirestorque archwires for division 2 cases, where additional torque are indicated
Out of stock
-
.019 x .025 34mm Nitanium Pro Form - 20 degrees Torque Archwire
Ref# : 103-111
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch. 34mm Options: Duration 4 - 6 weeks (Upper only) A) .017 x .025 and .019 x .025 Nitanium Arcwirestorque archwires for division 2 cases, where additional torque are indicated
Out of stock
-
.019 x .025 38mm Nitanium Pro Form - 20 degrees Torque Archwire
Ref# : 103-112
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch. 38mm Options: Duration 4 - 6 weeks (Upper only) A) .017 x .025 and .019 x .025 Nitanium Arcwirestorque archwires for division 2 cases, where additional torque are indicated
Out of stock
-
.017 x .025 Nitanium Super Elastic RCS Archwire
Ref# : 103-113
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch. Options: Duration 4 - 6 weeks (Upper only) B) .017 x .025 and .019 x .025 Nitanium Super Elastic RCS Archwires - for division 2 cases, where intrusion is indicatedOut of stock
-
.019 x .025 Nitanium Super Elastic RCS Archwire
Ref# : 103-114
10 - 20 Weeks
Objective: Finish aligning/leveling, resolve remaining rotation issues; begin torque control, angulations and space consolidations in the anterior; and continue developing arch. Options: Duration 4 - 6 weeks (Upper only) B) .017 x .025 and .019 x .025 Nitanium Super Elastic RCS Archwires - for division 2 cases, where intrusion is indicatedOut of stock